Vaillant ol kod blong eror mo minim blong olgeta · Vanuatu

Olgeta 15 kod blong trabol blong Vaillant long wan tebol: wanem wanwan i min, hamas i nogud mo wetaem blong singaot man blong wok.

KodMasinWanem i min
F.00gas boilerThe flow (outgoing) temperature sensor is disconnected or broken.
F.01gas boilerThe return temperature sensor is disconnected or broken.
F.10gas boilerThe flow (outgoing) temperature sensor has a short circuit.
F.11gas boilerThe return temperature sensor has a short circuit.
F.20gas boilerThe boiler overheated and the safety temperature limiter cut it out.
F.22gas boilerThe water pressure in the heating system is too low.
F.23gas boilerThe temperature difference between flow and return is too large, usually because water is not circulating well.
F.24gas boilerThe boiler temperature is rising too fast, usually because water is not circulating well (air, closed valves or a pump problem).
F.25gas boilerThe flue gas temperature is too high, or the flue or air supply is faulty or blocked.
F.28gas boilerThe boiler failed to ignite (no flame was detected) and has locked out.
F.29gas boilerThe flame went out during operation, or the flame sensor signal is faulty.
F.32gas boilerThe fan is faulty or is not reaching the correct speed.
F.61gas boilerThe boiler cannot actuate its gas valve, which indicates a fault in the gas valve assembly.
F.63gas boilerThe memory chip (EEPROM) on the boiler's control board is faulty.
F.75gas boilerThe boiler did not detect the expected pressure change when the pump started.