Makhodi a zolakwika a Vaillant ndi tanthauzo lake · Malawi

Ma code onse 15 a zolakwika a Vaillant patebulo limodzi: tanthauzo la lililonse, kuopsa kwake ndi nthawi yoitana mmisiri.

KhodiChipangizoTanthauzo lake
F.00boiler ya gasiThe flow (outgoing) temperature sensor is disconnected or broken.
F.01boiler ya gasiThe return temperature sensor is disconnected or broken.
F.10boiler ya gasiThe flow (outgoing) temperature sensor has a short circuit.
F.11boiler ya gasiThe return temperature sensor has a short circuit.
F.20boiler ya gasiThe boiler overheated and the safety temperature limiter cut it out.
F.22boiler ya gasiThe water pressure in the heating system is too low.
F.23boiler ya gasiThe temperature difference between flow and return is too large, usually because water is not circulating well.
F.24boiler ya gasiThe boiler temperature is rising too fast, usually because water is not circulating well (air, closed valves or a pump problem).
F.25boiler ya gasiThe flue gas temperature is too high, or the flue or air supply is faulty or blocked.
F.28boiler ya gasiThe boiler failed to ignite (no flame was detected) and has locked out.
F.29boiler ya gasiThe flame went out during operation, or the flame sensor signal is faulty.
F.32boiler ya gasiThe fan is faulty or is not reaching the correct speed.
F.61boiler ya gasiThe boiler cannot actuate its gas valve, which indicates a fault in the gas valve assembly.
F.63boiler ya gasiThe memory chip (EEPROM) on the boiler's control board is faulty.
F.75boiler ya gasiThe boiler did not detect the expected pressure change when the pump started.

Makhodi a zovuta za zipangizo malinga ndi mtundu

Funsani amisiri za ntchito yanu