MsimboKifaaMaana yake
F.00boiler ya gesiThe flow (outgoing) temperature sensor is disconnected or broken.
F.01boiler ya gesiThe return temperature sensor is disconnected or broken.
F.10boiler ya gesiThe flow (outgoing) temperature sensor has a short circuit.
F.11boiler ya gesiThe return temperature sensor has a short circuit.
F.20boiler ya gesiThe boiler overheated and the safety temperature limiter cut it out.
F.22boiler ya gesiThe water pressure in the heating system is too low.
F.23boiler ya gesiThe temperature difference between flow and return is too large, usually because water is not circulating well.
F.24boiler ya gesiThe boiler temperature is rising too fast, usually because water is not circulating well (air, closed valves or a pump problem).
F.25boiler ya gesiThe flue gas temperature is too high, or the flue or air supply is faulty or blocked.
F.28boiler ya gesiThe boiler failed to ignite (no flame was detected) and has locked out.
F.29boiler ya gesiThe flame went out during operation, or the flame sensor signal is faulty.
F.32boiler ya gesiThe fan is faulty or is not reaching the correct speed.
F.61boiler ya gesiThe boiler cannot actuate its gas valve, which indicates a fault in the gas valve assembly.
F.63boiler ya gesiThe memory chip (EEPROM) on the boiler's control board is faulty.
F.75boiler ya gesiThe boiler did not detect the expected pressure change when the pump started.