Vaillant ýalňyşlyk kodlary we olaryň manysy · Türkmenistan

Vaillant · ähli 15 näsazlyk kody bir tablisada: her biri näme aňladýar, näçe çynlakaý we haçan ussa çagyrmaly.

KodEnjamManysy
F.00gaz gazanThe flow (outgoing) temperature sensor is disconnected or broken.
F.01gaz gazanThe return temperature sensor is disconnected or broken.
F.10gaz gazanThe flow (outgoing) temperature sensor has a short circuit.
F.11gaz gazanThe return temperature sensor has a short circuit.
F.20gaz gazanThe boiler overheated and the safety temperature limiter cut it out.
F.22gaz gazanThe water pressure in the heating system is too low.
F.23gaz gazanThe temperature difference between flow and return is too large, usually because water is not circulating well.
F.24gaz gazanThe boiler temperature is rising too fast, usually because water is not circulating well (air, closed valves or a pump problem).
F.25gaz gazanThe flue gas temperature is too high, or the flue or air supply is faulty or blocked.
F.28gaz gazanThe boiler failed to ignite (no flame was detected) and has locked out.
F.29gaz gazanThe flame went out during operation, or the flame sensor signal is faulty.
F.32gaz gazanThe fan is faulty or is not reaching the correct speed.
F.61gaz gazanThe boiler cannot actuate its gas valve, which indicates a fault in the gas valve assembly.
F.63gaz gazanThe memory chip (EEPROM) on the boiler's control board is faulty.
F.75gaz gazanThe boiler did not detect the expected pressure change when the pump started.

Brendler boýunça enjam näsazlyk kodlary

Ussalardan işiňiz barada soraň

Başga dillerde: English