Vaillant: amakhodi amaphutha nezincazelo zawo · iNingizimu Afrika

Wonke amakhodi amaphutha angu-15: Vaillant, etafuleni elilodwa: ukuthi ngalinye lisho ukuthini, kubi kangakanani nokuthi ungabiza nini umsebenzi.

IkhodiInsizaKusho ini
F.00i-boiler kagesiThe flow (outgoing) temperature sensor is disconnected or broken.
F.01i-boiler kagesiThe return temperature sensor is disconnected or broken.
F.10i-boiler kagesiThe flow (outgoing) temperature sensor has a short circuit.
F.11i-boiler kagesiThe return temperature sensor has a short circuit.
F.20i-boiler kagesiThe boiler overheated and the safety temperature limiter cut it out.
F.22i-boiler kagesiThe water pressure in the heating system is too low.
F.23i-boiler kagesiThe temperature difference between flow and return is too large, usually because water is not circulating well.
F.24i-boiler kagesiThe boiler temperature is rising too fast, usually because water is not circulating well (air, closed valves or a pump problem).
F.25i-boiler kagesiThe flue gas temperature is too high, or the flue or air supply is faulty or blocked.
F.28i-boiler kagesiThe boiler failed to ignite (no flame was detected) and has locked out.
F.29i-boiler kagesiThe flame went out during operation, or the flame sensor signal is faulty.
F.32i-boiler kagesiThe fan is faulty or is not reaching the correct speed.
F.61i-boiler kagesiThe boiler cannot actuate its gas valve, which indicates a fault in the gas valve assembly.
F.63i-boiler kagesiThe memory chip (EEPROM) on the boiler's control board is faulty.
F.75i-boiler kagesiThe boiler did not detect the expected pressure change when the pump started.