ລະຫັດຂໍ້ຜິດພາດ Vaillant ແລະ ຄວາມໝາຍ · ລາວ

ລະຫັດຂໍ້ຜິດພາດ Vaillant ທັງ 15 ລະຫັດໃນຕາຕະລາງດຽວ: ແຕ່ລະອັນໝາຍເຖິງຫຍັງ, ຮ້າຍແຮງສ່ຳໃດ ແລະ ເວລາໃດຄວນເອີ້ນຊ່າງ.

ລະຫັດເຄື່ອງໃຊ້ໄຟຟ້າໝາຍຄວາມວ່າແນວໃດ
F.00ໝໍ້ຕົ້ມນ້ຳແກັສThe flow (outgoing) temperature sensor is disconnected or broken.
F.01ໝໍ້ຕົ້ມນ້ຳແກັສThe return temperature sensor is disconnected or broken.
F.10ໝໍ້ຕົ້ມນ້ຳແກັສThe flow (outgoing) temperature sensor has a short circuit.
F.11ໝໍ້ຕົ້ມນ້ຳແກັສThe return temperature sensor has a short circuit.
F.20ໝໍ້ຕົ້ມນ້ຳແກັສThe boiler overheated and the safety temperature limiter cut it out.
F.22ໝໍ້ຕົ້ມນ້ຳແກັສThe water pressure in the heating system is too low.
F.23ໝໍ້ຕົ້ມນ້ຳແກັສThe temperature difference between flow and return is too large, usually because water is not circulating well.
F.24ໝໍ້ຕົ້ມນ້ຳແກັສThe boiler temperature is rising too fast, usually because water is not circulating well (air, closed valves or a pump problem).
F.25ໝໍ້ຕົ້ມນ້ຳແກັສThe flue gas temperature is too high, or the flue or air supply is faulty or blocked.
F.28ໝໍ້ຕົ້ມນ້ຳແກັສThe boiler failed to ignite (no flame was detected) and has locked out.
F.29ໝໍ້ຕົ້ມນ້ຳແກັສThe flame went out during operation, or the flame sensor signal is faulty.
F.32ໝໍ້ຕົ້ມນ້ຳແກັສThe fan is faulty or is not reaching the correct speed.
F.61ໝໍ້ຕົ້ມນ້ຳແກັສThe boiler cannot actuate its gas valve, which indicates a fault in the gas valve assembly.
F.63ໝໍ້ຕົ້ມນ້ຳແກັສThe memory chip (EEPROM) on the boiler's control board is faulty.
F.75ໝໍ້ຕົ້ມນ້ຳແກັສThe boiler did not detect the expected pressure change when the pump started.

ລະຫັດຂໍ້ຜິດພາດເຄື່ອງໃຊ້ໄຟຟ້າແຍກຕາມຍີ່ຫໍ້