РамзДастгоҳМаъноаш чист
F.00дегбухори газиThe flow (outgoing) temperature sensor is disconnected or broken.
F.01дегбухори газиThe return temperature sensor is disconnected or broken.
F.10дегбухори газиThe flow (outgoing) temperature sensor has a short circuit.
F.11дегбухори газиThe return temperature sensor has a short circuit.
F.20дегбухори газиThe boiler overheated and the safety temperature limiter cut it out.
F.22дегбухори газиThe water pressure in the heating system is too low.
F.23дегбухори газиThe temperature difference between flow and return is too large, usually because water is not circulating well.
F.24дегбухори газиThe boiler temperature is rising too fast, usually because water is not circulating well (air, closed valves or a pump problem).
F.25дегбухори газиThe flue gas temperature is too high, or the flue or air supply is faulty or blocked.
F.28дегбухори газиThe boiler failed to ignite (no flame was detected) and has locked out.
F.29дегбухори газиThe flame went out during operation, or the flame sensor signal is faulty.
F.32дегбухори газиThe fan is faulty or is not reaching the correct speed.
F.61дегбухори газиThe boiler cannot actuate its gas valve, which indicates a fault in the gas valve assembly.
F.63дегбухори газиThe memory chip (EEPROM) on the boiler's control board is faulty.
F.75дегбухори газиThe boiler did not detect the expected pressure change when the pump started.