KodTexnikaNə deməkdir
F.00qaz qazanıThe flow (outgoing) temperature sensor is disconnected or broken.
F.01qaz qazanıThe return temperature sensor is disconnected or broken.
F.10qaz qazanıThe flow (outgoing) temperature sensor has a short circuit.
F.11qaz qazanıThe return temperature sensor has a short circuit.
F.20qaz qazanıThe boiler overheated and the safety temperature limiter cut it out.
F.22qaz qazanıThe water pressure in the heating system is too low.
F.23qaz qazanıThe temperature difference between flow and return is too large, usually because water is not circulating well.
F.24qaz qazanıThe boiler temperature is rising too fast, usually because water is not circulating well (air, closed valves or a pump problem).
F.25qaz qazanıThe flue gas temperature is too high, or the flue or air supply is faulty or blocked.
F.28qaz qazanıThe boiler failed to ignite (no flame was detected) and has locked out.
F.29qaz qazanıThe flame went out during operation, or the flame sensor signal is faulty.
F.32qaz qazanıThe fan is faulty or is not reaching the correct speed.
F.61qaz qazanıThe boiler cannot actuate its gas valve, which indicates a fault in the gas valve assembly.
F.63qaz qazanıThe memory chip (EEPROM) on the boiler's control board is faulty.
F.75qaz qazanıThe boiler did not detect the expected pressure change when the pump started.